Hyperbaric Oxygen Chambers | Pioneer Trades
Wellness & recovery equipment · HBOT

Hard-shell hyperbaric oxygen chambers

A complete range of seated and lying hard-shell chambers, adjustable from 1.1 to 2.0 ATA, for wellness centres, clinics, spas, sports facilities and private residences. Every chamber is supplied with delivery, installation, commissioning, operator training and after-sales support by Pioneer Trades.

Shell Cabin hard-shell hyperbaric chamber with its 3-in-1 main unit
  • 1.1–2.0 ATAAdjustable treatment pressure
  • 90–96%Oxygen at the mask from a built-in generator, no cylinders
  • 24 VLow-voltage, anti-static chamber interior
  • 35–66 sEmergency depressurisation from 1.3 to 2.0 ATA
The range

Five chamber designs, one service standard

Choose by space, capacity and how your clients prefer to sit or lie. All models share the same 3-in-1 main unit concept, safety systems and support package.

Shell Cabin hyperbaric chamber
Clamshell cabin · 1 or 2 persons

Shell Cabin

A rounded cabin in aviation-grade magnesium-aluminium alloy. At 330 kg for the one-person model it is the lightest hard shell in the range and kinder to residential floors. It splits into two halves for delivery through standard doorways and has a horizontal sliding door.

Pressure
Up to 2.0 ATA
Footprint
2.0 × 1.0 m (1 p) · 2.0 × 1.5 m (2 p)
Weight
330 kg · 380 kg

HomesGymsSpas

Capsule Seated hyperbaric chamber
Full-size seated capsule · 1 person

Capsule Seated

A full-size steel capsule with a 65-inch-deep cabin and a zero-gravity electric reclining seat. It is built for premium home, home-gym and clinic installations that run regular sessions at 1.5 to 2.0 ATA.

Pressure
1.1–2.0 ATA
Size
2070 × 2000 × 1750 mm
Weight
700 kg

ClinicsHomesRecovery studios

Orbit Seated hyperbaric chamber
Round seated pod · 1 or 2 seats

Orbit Seated

A statement pod in pressure-resistant steel alloy with an eco powder-coat finish. It has a CNC-machined door frame with aviation-grade polycarbonate and 10-inch touch screens inside and out. The main unit is the most powerful in the range at 20 L/min.

Pressure
1.1–2.0 ATA
Size
1780 × 1352 × 1808 mm
Weight
620 kg

Wellness centresHotelsSpas

Orbit Mini hyperbaric chamber
Compact upright pod · 1 person

Orbit Mini

The Orbit design in a narrow, under-one-metre footprint, for rooms where floor space is limited. It keeps the electric reclining seat, dual touch screens and the full 2.0 ATA rating.

Pressure
1.1–2.0 ATA
Size
1780 × 984 × 1990 mm
Weight
560 kg

HomesClinicsSmall spaces

Recline Capsule lying hyperbaric chamber
Lying capsule · 1 person

Recline Capsule

A one-piece cast aluminium alloy capsule for lying-down sessions, comfortable for long sessions or rest. It is light enough for most floors and comes in 1.5 ATA and 1.9 ATA versions.

Pressure
1.5 or 1.9 ATA
Size
2300 mm long · Ø 750 mm
Weight
≈ 90–110 kg

HomesClinicsAthletes

Technical comparison

Specifications at a glance

SpecificationShell CabinCapsule SeatedOrbit SeatedOrbit MiniRecline Capsule
PositionSeated / reclinedSeated / reclinedSeated / reclinedSeated / reclinedLying
Capacity1 or 2 persons1 person1 or 2 persons1 person1 person
Working pressureUp to 2.0 ATA1.1–2.0 ATA1.1–2.0 ATA1.1–2.0 ATA1.5 or 1.9 ATA
Shell materialAviation-grade Mg-Al alloyNickel-steel alloySteel alloy, powder-coatedSteel alloy, powder-coatedCast aluminium alloy
Chamber size (L × W × H)2000 × 980 × 1700 mm (1 p)
2000 × 1480 × 1700 mm (2 p)
2070 × 2000 × 1750 mm1780 × 1352 × 1808 mm1780 × 984 × 1990 mm2300 mm × Ø 750 mm
Chamber net weight330 kg (1 p) · 380 kg (2 p)700 kg620 kg560 kg≈ 90–110 kg
Oxygen flow (main unit)15 L/min (20 L/min option)15 L/min20 L/min15 L/min1–10 or 1–15 L/min
Oxygen purity (main unit)90% ± 3%90% ± 3%93% ± 3%93% ± 3%≥ 90% ± 3%
Main unit power850–1100 W (1 p)
1000–2200 W (2 p)
1100 W1500 W1500 W850 W / 1100 W
Main unit size · weight570 × 520 × 905 mm · 85 kg570 × 520 × 905 mm · 85 kg800 × 410 × 870 mm · 100 kg800 × 410 × 870 mm · 100 kg590 × 520 × 903 mm · 82–85 kg
Main unit noise≤ 50 dB≤ 50 dB≤ 63 dB≤ 63 dB—
ControlsTouch panels inside & outsideTouch panels inside & outside10" touch screens inside & outside10" touch screens inside & outside9" touch screens
ColoursBlack · WhiteBlack · White · GreyBlack · White · SilverBlack · White · SilverWhite

Specifications are indicative and may be refined by the factory. The final configuration, electrical rating (220–230 V 50 Hz or 110 V 60 Hz) and documentation are confirmed in each quotation.

Inside every chamber

Comfort and clean air as standard

The seated models share one premium cabin specification, so every chamber offers the same experience.

  • Zero-gravity electric seat. Aviation-grade reclining sofa that moves from seated to reclined at the touch of a button.
  • Oxygen headset and mask. One oxygen set per seat, with an optional built-in breathing system (BIBS).
  • Dual touch controls. Session controls inside the cabin and at the operator console outside.
  • Clear polycarbonate door. An aviation-grade pressure door gives a bright, open feel.
  • Medical-grade air filtration. 5 µm filtration, negative-ion and IFD physical air sterilisation with no chemicals.
  • Climate and humidity control. Water-cooled air conditioning (5–55 °C range) and a built-in dehumidifier.
  • Quiet cabin. Interior noise of 20 dB or less, with ambient lighting and flame-retardant carpets and upholstery.
3-in-1 main unit

Air, oxygen and cooling in one console

Each chamber is paired with a compact main unit that houses the air compressor, the oxygen generator and the air conditioning. It runs from a single touch screen.

PSA oxygen generation

A twin-tower pressure-swing-adsorption generator makes oxygen from room air and delivers 90–96% to the user. No oxygen cylinders to buy, store or refill.

Pressure regulation

Automatic, multi-stage pressure control holds the set pressure steadily and runs smooth pressurisation and decompression cycles.

Climate control

Water-cooled air conditioning keeps the cabin comfortable through the session. A closed-loop cooling option is available for sites without plumbing.

Safety engineering

Designed around oxygen and pressure safety

Every model carries the same layered protection: continuous monitoring, automatic interlocks and manual emergency release from inside and outside the chamber.

  • Oxygen monitoring with interlock. Cabin oxygen is held at 25–29%. A warning sounds at 28%, and at 30% the system forces ventilation.
  • CO₂ monitoring. In-chamber sensors trigger alarms and increase fresh-air exchange automatically.
  • Exhaled air vented outside. With BIBS, exhaled air leaves through dedicated piping and never recirculates in the cabin.
  • 24 V anti-static interior. Low-voltage electrics rated for oxygen-enriched use, with no spark or heat sources in the cabin.
  • Flame-retardant materials. Carpets, leather and upholstery meet US CAL TB117:2013.
  • Manual emergency release. Relief valves inside and outside the chamber work without electrical power.
  • Two-way intercom and emergency call. The occupant can speak to the operator throughout, and a call button alerts the console.
  • Over-pressure and over-temperature protection. Dual protection with automatic shutdown of pressurisation.
Indicative cycle times
PressurePressuriseNormal releaseEmergency release
1.3 ATA≈ 4 min≈ 3 min 55 s≈ 35 s
1.5 ATA≈ 7 min≈ 4 min≈ 45 s
1.8 ATA≈ 13 min≈ 4 min 40 s≈ 59 s
2.0 ATA≈ 15 min≈ 5 min≈ 66 s
Options & upgrades

Build a complete recovery suite

  • BIBS breathing systemBuilt-in breathing circuit with mask, headset or cannula, and exhaled air vented outside
  • Red light therapy panelsIn-chamber panels to pair HBOT with red light sessions
  • Oxygen humidifierReduces dryness of the nose and throat during longer sessions
  • Entertainment screenIn-cabin TV for the two-person Shell Cabin
  • Closed-loop coolingAir conditioning without a mains water supply or drainage
  • Colours & voltageFactory colours and 220–230 V or 110 V configurations to suit your market
Our service

More than a chamber: we deliver a working installation

We manage the whole project from first enquiry to handover and support you after installation, in the UAE, across the GCC and for international projects.

  1. Consultation & model selectionWe match the chamber to your space, capacity, pressure needs and budget.
  2. Site survey & readinessWe check floor loading, access, power, ventilation and water, then both parties sign a readiness checklist before shipment.
  3. Shipping & deliveryTwo IPPC-certified wooden crates per set. We arrange freight, customs clearance and delivery to site.
  4. Installation & commissioningWe position the chamber and test electrical safety, air-tightness, pressure cycles, oxygen alarms and emergency release at rated pressure.
  5. Acceptance & trainingA 72-hour trial run, a signed acceptance certificate and hands-on operator training.
  6. Warranty & after-sales1-year warranty, extendable by 2 years, with 24/7 remote diagnosis, spare parts by air in 3–5 working days and planned maintenance.
Planning guide

Preparing your site

We confirm the exact requirements for your model during the site survey. As a general guide:

Floor

Reinforced concrete with a uniformly distributed load of at least 550 kg/m². Suspended timber and raised floors are not suitable. Complete sets weigh from about 200 kg (Recline Capsule) to 800 kg (Capsule Seated).

Access & room

A doorway at least 1.1 m wide and 2.0 m high, or less for the Shell Cabin, which splits in two. Allow 1.2 m service space along the length, 0.8 m across the width and 0.5 m above the chamber.

Ventilation

At least 6 air changes per hour, with exhaust and excess-oxygen vent lines ducted directly outdoors. Keep the room at 18–28 °C and out of direct sun.

Power

A dedicated single-phase circuit with overload protection, and independent earthing of 4 Ω or less. Wiring is concealed.

Cooling water

Clean or softened water at 15–25 °C and 0.2–0.4 MPa, 10–20 L/min. Alternatively, choose the closed-loop cooling option.

Maintenance

Daily pre-use checks, quarterly calibration of oxygen and CO₂ sensors, an annual inspection of the safety accessories and periodic pressure-vessel inspection.

Responsible use

Safety and suitability

Hyperbaric oxygen is not suitable for everyone. Every user should be screened before their first session, and operators must be trained in normal and emergency procedures.

Not to be used with untreated pneumothorax, uncontrolled seizures, active bleeding or high bleeding risk, severe uncontrolled lung disease, or if the user cannot follow the safety procedures.

Medical assessment first for pregnancy, recent ear surgery or difficulty equalising ear pressure, upper respiratory infection or sinusitis, high fever, COPD, severe heart or lung insufficiency, uncontrolled hypertension or claustrophobia.

Regulatory note. The chambers are supplied as wellness equipment. Using HBOT for medical treatment requires the facility licensing, device registration and clinical supervision set by the relevant health authority, such as MOHAP, DHA or DOH in the UAE. We can advise on the requirements for your project.

Questions

Frequently asked

Do I need oxygen cylinders?

No. The main unit generates oxygen from room air using PSA technology, so there are no cylinders to buy, store or refill.

Will the chamber fit through my door?

Most models need a doorway of at least 1.1 × 2.0 m. The Shell Cabin splits into two halves for narrower access. We confirm access during the site survey before anything ships.

Can it be installed in an apartment or villa?

Yes, if the floor is reinforced concrete and rated for the load. The aluminium Shell Cabin and Recline Capsule are the lightest options for residential floors.

Which pressure should I choose?

Wellness and recovery programmes commonly run at 1.3–1.5 ATA. Higher settings up to 2.0 ATA are used under trained supervision. We configure the pressure range to your intended use and local rules.

What warranty and support do I get?

A 1-year warranty, extendable by 2 years, and lifetime technical support. Faults are diagnosed remotely first, parts are dispatched by air in 3–5 working days, and on-site service is arranged when needed.

How long does delivery take?

Lead time depends on the model, colour and options. We confirm production and shipping times in your quotation.

Get In Touch

Start a conversation

Tell us the chamber you are interested in and where it will be installed. We will respond within one business day with a recommendation, specification and quotation.

Ready to talk?

Book a 30-minute discovery call at a time that suits you, or send us your chamber requirements and we will reply within one business day with a quotation.

Book a Call on Calendly ↗

Request a Quotation